Overhauled Code for Carbon Monoxide Detectors Now Applies to Commercial Buildings

Nov. 26, 2008
Greater awareness of the lethal nature of carbon monoxide (CO) has given rise to increasing numbers of state and local building codes related to CO. Although the National Fire Protection Association (NFPA) has had a CO code for dwelling units for some time, it has not had a CO code for commercial buildings – until now.

The NFPA has released the 2009 edition of the CO code, NFPA 720, and industry professionals and management in the commercial building field need to pay attention to how this far-reaching code will affect them. The new code, which is a complete rewrite of the CO detection standard, covers commercial occupancies as well as residences. The 2009 edition also requires significant changes in terms of CO detector development, installation, testing and off-premise signal transmission.

According to System Sensor, a St. Charles, Ill., manufacturer of fire and life safety systems, building and safety managers need to be aware of how this code affects their facilities. NFPA 720, for example, calls for placement of CO detectors on every habitable level and in every HVAC zone of the building. Other notable changes include:

  • CO detectors must be distinct from fire alarms and other devices. Plus, devices must have an integral trouble relay that will send trouble conditions to the control panel, such as a sensor failure or sensor end-of-life signal.
  • The code specifies requirements for secondary power supplies for CO detection systems and how that requirement differs depending on whether the notification applications are connected to a supervising station.

Many authorities having jurisdiction, such as fire inspectors, as well as engineers and building owners have requested the ability to test a CO detector just as they are able to test a smoke detector with canned smoke. NFPA 720 does not yet require CO device testing, however, some new detectors on the market already meet this testing requirement.

NFPA 720 – Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment 2009 Edition is available in print and PDF format at http://www.nfpa.org.
About the Author

Sandy Smith

Sandy Smith is the former content director of EHS Today, and is currently the EHSQ content & community lead at Intelex Technologies Inc. She has written about occupational safety and health and environmental issues since 1990.

Sponsored Recommendations

Ensuring a Safer Workplace through a Comprehensive Contractor Qualification Framework

March 13, 2025
Avetta is a leader in contractor management, and with over 15 years of industry experience, we can help you establish a robust contractor pre-qualification program that aligns...

EQT Private Equity to Acquire Avetta from WCAS

March 13, 2025
EQT commits to supporting Avetta in its ongoing growth and innovation journey.

Guide to OSHA Workplace Lighting Requirements

March 13, 2025
Learn OSHA workplace lighting requirements to enhance safety, productivity, and quality. Discover standards, compliance benefits, and risks of non-compliance.

What is the difference between Tier 1, 2, and 3 suppliers and why do they matter?

March 13, 2025
From raw materials to final products, each supplier tier poses risks and liabilities that can impact your organization. Avetta's supply chain management software offers peace ...

Voice your opinion!

To join the conversation, and become an exclusive member of EHS Today, create an account today!